Tweak the gutter relation to height to obtain different gutter sizes.
Width to depth gutter ratio.
At this point follow a horizontal line to the left until the vertical line of rainfall intensity x design area ia is crossed.
Maximum gutter per ds refers to the maximum length of gutter that is to be served by one downspout.
Capacity for rectangular roof gutters.
Depth of gutter 0 75 x width.
Q 1 486 x s 0 667 with n 0 012 for smooth metal smooth concrete or planed lumber and p wetted perimeter in feet.
The slope will take input as either an integer e g.
A depth width ratio of 0 75 the required gutter width is 5 1 inches.
Capacities calculated using manning s formula for open channel flow.
Wp56 the optimum sizing of gutters for domestic roofwater harvesting.
To do this a ratio m which equals the depth divided by the width is initially assumed.
Compute depth of flow and ponded width t in the gutter section at the inlet.
3 or a ratio to 12 e g.
Depth of gutter 0 75 x width.
The capacity of a sloped rectangular gutter may be approximated by using a gutter cross section area not less than that of a semicircular gutter and a depth to width ratio of at least 0 75.
Determine the ratio of the width of flow in the depressed section w to the width of total gutter flow t using equation 10 5.
Plan width and plan length should be flat plan dimensions not calculated along the slope.
For a depth width ratio of 0 75 and a rectangular gutter width of 6 inches the depth should be 4 5 inches deep.
The standard is about inch per 10 feet.
As with gutters a downspout s capacity must match or exceed the expected runoff.
Ratio of depth to width of gutter select gutter ratio 0 125x 0 25x 0 375x 0 5x 0 625x 0 75x 0 875x 1x 1 125x 1 25x 1 375x 1 5x 1 625x 1 75x 1 875x 2x calculate drainage reset.
Iii a u shaped or trapezoidal section gutter of width only 70 mm will be sufficient for most house roofs in the tropics.
The width depth w d ratio is defined as the ratio of the bankfull surface width to the mean depth of the bankfull channel.
The above recommendations assume that you have properly sized downspouts every 40 feet.
Starting with the length of the gutter l follow a vertical line until the ratio m is reached.
Capacities calculated using manning s formula for open channel flow.
The optimum gutter location and fixing trajectory are also explored to produce recommendations.